RocGene (Beijing) Technology Co., Ltd.
Application Requirements
Rapid diagnosis of pet diseases (such as cat/canine distemper, etc.) is a key link in preventing and controlling the spread of the epidemic, reducing economic losses in the breeding industry, and ensuring the health of pets. Traditional laboratory testing methods (e.g., virus isolation, enzyme-linked immunosorbent assays) are less accurate, time-consuming, and unfriendly to field applications, and cannot meet the need for rapid diagnosis and decision-making of diseases. Therefore, convenient, efficient, and sensitive molecular testing tools are needed to enable rapid on-site diagnosis and emergency management.
Solutions
Point-of-Care Testing (POCT) Solution - iFIND
Sample Processing: Built-in ultrasound combined with chemical lysis + high-efficiency microfiltration membrane purification.
System Construction: Fully enclosed cartridge with prefabricated lyophilized reagents and automatic system preparation.
Detection Results: Thin-film reaction zone with average temperature change rate ≥10℃/S, ultra-multiplex detection achieved through multiple probes + probe melting curve.
Open Workstation Solution - Atlas120
Sample Processing: Supports fully automatic nucleic acid extraction for up to 12 samples simultaneously.
System Construction: Open detection reagents, robotic arm for automated reaction system preparation,全程 liquid-sealed for pollution-free operation.
Detection Results: Standard real-time fluorescent quantitative PCR reaction, supporting amplification and melting curve analysis, etc. 6-color fluorescence with 4 amplification detection positions per sample, supporting detection of 24 targets.
Rapid Response Solution - ArchiPure+Archimed Mini/Mini Pro/R
Sample Processing: High-purity nucleic acid extraction from samples (e.g., nasopharyngeal swabs, throat swabs) using fully automatic nucleic acid extractor, improving sensitivity and reliability of subsequent detection.
System Construction: Manual preparation of detection system or use of Rocgene lyophilized ready-to-use reagents.
Detection Results: Real-time fluorescent quantitative PCR instrument combined with multiplex PCR technology, supporting amplification and melting curve analysis, etc. Standard configuration with 4-color fluorescence and 16/96 throughput. Enables rapid detection of samples with various throughputs.
Mobile Detection Solution - ArchiSuit/Archimed Mini Pro Detection Backpack
Sample Processing: High-purity nucleic acid extraction from samples (e.g., nasopharyngeal swabs, throat swabs) using 16/32 throughput fully automatic nucleic acid extractor, improving sensitivity and reliability of subsequent detection.
System Construction: Manual preparation of detection system or use of Rocgene lyophilized ready-to-use reagents.
Detection Results: Miniaturized 16-throughput real-time fluorescent quantitative PCR instrument combined with multiplex PCR technology, supporting amplification and melting curve analysis, etc. Standard configuration with 4-color fluorescence, meeting daily detection needs of standard throughput experiments.
Application Scenarios
  • Animal or Pet Hospitals
    Accurately identify the infection source of animals or pets to assist veterinarians in making accurate diagnoses and provide a basis for timely formulation of treatment plans. Suitable for Point-of-Care Testing (POCT), Open Workstation and Rapid Response solutions.
    Large-scale Breeding Centers, etc.
    For daily pathogen monitoring in breeding centers, animals/pets with infectious symptoms, seedling introduction, finished product slaughter, female animal abortion, etc., it is necessary to quickly determine the type of pathogenic bacteria and drug-resistant gene carrying status, distinguish between single strain outbreak or mixed infection, provide a basis for precise medication and whole group prevention and control. Suitable for POCT, Open Workstation and Rapid Response solutions.
    Small-scale Farms or Pet Stores
    Daily infection prevention and diagnosis of suspected patients, only need to meet basic testing needs. Suitable for Mobile Detection Solution or Rapid Response Solution.
    Third-party Testing Service Institutions
    Provide disease infection testing services for places without biological experiment conditions. Select Point-of-Care Testing (POCT), Open Workstation, Rapid Response or Mobile Detection solutions according to service objects and the number of test samples.
Detection Process
Point-of-Care Testing (POCT) Solution - iFIND
Open Workstation Solution - Atlas 120
Rapid Response Solution - ArchiPure+Archimed Mini/MiniPro/R
Mobile Detection Solution - ArchiSuit/ArchimedMini Pro Detection Backpack
Our Advantages
01
High-Efficiency Detection
All solutions support multiplex detection. The POCT solution can complete testing within half an hour, while the workstation and rapid response solutions save more than 20% of the time compared with conventional instruments.
02
Excellent Sensitivity and Specificity
Combined with automatic nucleic acid extraction and high-efficiency real-time fluorescent quantitative PCR, ensuring high sensitivity and strong specificity, reducing the risk of false positive/false negative results, and effectively lowering detection costs.
03
Wide Applicability
Multiple solutions support various sample types (e.g., swabs, blood, feces, etc.) to meet different needs.
04
Flexible Solution Design
Detection reagents can be adapted according to detection throughput requirements, with strong adaptability.
Successful Cases

Scenario: In pet hospitals, sample collection and testing are performed on dogs and cats with suspected epidemic symptoms such as fever, respiratory symptoms, and digestive tract symptoms to identify the infecting pathogens and assist clinicians in formulating personalized treatment plans.


Needs: The hospital's testing volume is mainly concentrated on weekends, and it does not have a professional molecular testing laboratory. The previous platform had cumbersome manual operation steps and serious pollution, and the test results could not correspond to the symptoms. There is an urgent need to replace it with a molecular platform that requires no manual operation, has strong anti-pollution capability, and provides accurate test results.


Solution:

With the Point-of-Care Testing (POCT) solution provided by Rocgene, laboratory personnel only need one-step sample addition with no additional operations required throughout the process, and the consumables remain fully enclosed during the testing process, fundamentally solving the problem of test result contamination and replacing the original outdated equipment.


Result Display:

After the pet was sampled in the store, the sample was added to the test cartridge, and the automated test showed a positive result for Chlamydia felis infection. The doctor diagnosed the pet according to specific symptoms and provided targeted treatment. One week later, the cat's clinical symptoms disappeared.

On-site Usage Photo
Test Result
Test Result
Continue to Company Website
Copyright © Rocgene (Beijing) Scientific Instruments Co., Ltd. - All Rights Powered by Bomin